Original Article

Vol. 26 No. 1 (2017): Turkish Journal of Nephrology Türk Nefroloji Derneği Dergisi TND Dergisi

Evaluation the Iron Load in Chronic Hemodialysis Patients with Fibroscan: A Preliminary Study

Main Article Content

Orçun ALTUNÖREN
Kadir GİŞİ
Tuğba YILMAZ
Ferhat KESLER
Murat İSPİROĞLU
Didem DEMİRCİOĞLU
Safa Ersen GANİDAĞLI
Yasemin COŞKUN YAVUZ
Ali ÇETİNKAYA
Özkan GÜNGÖR

Abstract

OBJECTIVE: Iron preperations are frequently used in hemodalysis (HD) patients and iron may accumulate liver and other tissues. Noninvasively methods are needed to detect liver iron accumulation in HD patients. Hepatic iron accumulation with Fibroscan was shown in non-renal population. In this study, we aim to investigate whether or not the hepatic iron load can be determined with Fibroscan in hemodialysis patients.



MATERIAL and METHODS: 42 chronic HD patients included this study. Serum iron, iron binding capasity, ferritin and transferrin saturation were used to determine iron status. Liver stiffness was measured by an experienced gastroenterolog with Fibroscan device.



RESULTS: While mean Fibroscan value was 9,15 kPa, ferritin was 565,99 mg/dl. Fibroscan value were positive correlated with transferrin saturation and ferritin but negative correlated with albumin. In multiple regression analysis, it was observed that only ferritin and albumin levels related with Fibroscan value.



CONCLUSION: This study showed that the stiffness of the liver increasing while the ferritin value increasing. This result might be due to iron accumulation in the liver. 


Article Details